| Model No. |
RX-30 |
RX-30A |
| Power input |
10 to 30V DC (without polarity) |
100V AC 50/60Hz |
| Power/ Current consumption |
300mA max. |
3W |
| Operating frequency band |
426MHz band
(wireless equipment of low power security system) |
| Antenna |
Helical antenna (incorporated) |
| Coverage distance |
Approx. 100m (line-of-sight distance) |
| Flash output |
Flash color: Red (high-brightness LED x 12)
Blinking frequency:
Repeats the cycle of lighting 4 times for approx. 0.4 sec. and one pause for 0.4 sec.
when the alarm is activated.
When shifting to protection: Lights ON once for approx. 0.2 sec.
When shifting to cancellation: Lights ON twice for approx. 0.6 sec.
(Lights for 0.2 sec., pauses for 0.2 sec. and lights for 0.2 sec.)
During memory display operation: Lights once in cycles of approx. 3 sec.
|
| Sound Output |
Sound volume:
Changeable from 0 to 70dB and more/ 1m using the sound volume when the alarm is
activated
A certain volume is kept when the alarm is set or cancel, regardless of the sound
volume
Sound cycle:
Alarm: Repeatedly outputs the message during the timer set time.
When shifting to protection: Rings once for approx. 0.2 sec. (synchronized with the
flash output)
When shifting to cancellation: Rings twice for approx. 0.6 sec. (synchronized with the
flash output) |
| Messages |
RX-30 (A08), RX-30A (A08): “Error has occurred”
RX-30 (A10), RX-30A (A10): “Someone has intruded” |
| Alarm output |
Contact type: Dry semiconductor contact (N.O.)
Contact operation:
Operates for the set time when “Timer operation” of alarm operation mode is set.
(10, 30, 120, 300 sec) Without retrigger
Operates in conjunction with the controller or contact point type transmitter when
“real time operation” of alarm operation mode is set.
(Maximum operation time is 10
minutes)
Contact rating: 24V AC/DC, 0.25A max.
(Resistive load)
Contact protection resistance 3Ω built in |
Power indicator
(green LED) |
Power ON: ON
Transmitter battery exhaustion alarm: Blinks (ON for 0.1 sec. and OFF for 0.6 sec.)
Blackout backup: Blinks (ON for 0.6 sec. and OFF for 0.6 sec.)
Only when the dedicated emergency power supply is used |
Reception indicator
(red LED) |
Reception: At the normal reception level: Lights for the reception time + 0.5 sec.
At the low reception level: Lights for the reception time + 4 sec. |
Allowable number of
registered transmitters |
50 units |
| Tamper operation |
Transmitter tamper:
Alarm operation for the timer set time when the tamper signal is received.
(Operates in conjunction with the controller operation when the units is used to operate with the controller)
Body tamper:
Alarm operation for the timer set time when the cover of the body is opened. |
| Alarm memory operation |
Notification after alarm activation: Flashlight ON with a period of once in approx. 3 sec.
(Continues until the time of shift to the protection state again, after reset.)
Notification after reset: Flashlight ON for 2 sec. and the alarm rings.
(Activates only with the unidirectional type remote controller used, when the unit is
used to operate with the controller) |
| Ambient temperature range |
-10°C to +50°C |
| Wiring |
Terminals |
| Mounting position |
Outdoor, indoor |
| Weight |
Approx. 500g |
Approx. 600g |
| Appearance |
Housing: AES resin Lens: PC resin |